The Duplex PNP200 two-stage gas manifold from GCE Medical is intended for use in hospital pipeline systems as a medical gas source.
The GCE Medical Duplex PNP200 gas manifold is designed for use in hospital pipeline systems as a reliable medical gas source. It efficiently reduces gas pressure in two stages, maintaining a consistent distribution pressure.
The Duplex PNP200 features an integrated third source entry point for LOX, a compressor, or a backup gas source. The innovative touchscreen alarm, included with the manifold, displays all three gas sources on the alarm screen for enhanced monitoring.
The automatic manifold delivers gas from the operating bank to the pressure regulator until the cylinders are depleted. Once the supply is exhausted, the system automatically switches to the reserve bank, allowing for seamless replenishment. This automatic switch is powered by a new, advanced pneumatic shuttle valve design.
The GCE Medical Duplex PNP200 gas manifold is designed for use in hospital pipeline systems as a reliable medical gas source. It efficiently reduces gas pressure in two stages, maintaining a consistent distribution pressure.
The Duplex PNP200 features an integrated third source entry point for LOX, a compressor, or a backup gas source. The innovative touchscreen alarm, included with the manifold, displays all three gas sources on the alarm screen for enhanced monitoring.
The automatic manifold delivers gas from the operating bank to the pressure regulator until the cylinders are depleted. Once the supply is exhausted, the system automatically switches to the reserve bank, allowing for seamless replenishment. This automatic switch is powered by a new, advanced pneumatic shuttle valve design.
All-in-One Control Panel
Manage all three gas sources seamlessly from a single panel to simplify operation and improve workflow efficiency.
Versatile Cylinder Compatibility
The manifold is compatible with 300 bar, 200 bar, and 150 bar cylinders to provide flexibility for various hospital setups.
Suitable for All Medical Gases
Designed to work with a wide range of medical gases for versatility.
Fully Automatic Changeover
Automatically switches to the reserve gas bank when the primary source is exhausted for uninterrupted gas supply without manual intervention.
Innovative Touchscreen Alarm
Equipped with a touchscreen alarm that provides real-time visual and audible notifications.
Real-Time Source Monitoring
The integrated alarm system continuously monitors all gas sources, displaying their status and offering visual cues for active sources.
Integrated Communication Protocols
Supports both MODBUS TCP/IP and RS485 RTU for easy integration with existing hospital systems and external monitoring devices.
Third Source Option
Includes an additional port for LOX, a compressor, or a third cylinder to provide flexibility for backup gas sources or specialised setups.
Leakage Monitoring for Safety
Monitors potential leakage on non-active sources, alerting users to any issues with the reserve side and enhancing overall system safety.
Maintenance Without Interruption
Perform service and maintenance operations while the manifold continues to function, ensuring no gas supply disruption during critical times.
Simple and Quick Installation
The manifold comes with a pre-installed back plate to simplify installation.
Optional Terminal Unit Test Point
Provides easy access for testing and servicing, ensuring the manifold operates efficiently and meets safety standards.
All-in-One Control Panel
Manage all three gas sources seamlessly from a single panel to simplify operation and improve workflow efficiency.
Versatile Cylinder Compatibility
The manifold is compatible with 300 bar, 200 bar, and 150 bar cylinders to provide flexibility for various hospital setups.
Suitable for All Medical Gases
Designed to work with a wide range of medical gases for versatility.
Fully Automatic Changeover
Automatically switches to the reserve gas bank when the primary source is exhausted for uninterrupted gas supply without manual intervention.
Innovative Touchscreen Alarm
Equipped with a touchscreen alarm that provides real-time visual and audible notifications.
Real-Time Source Monitoring
The integrated alarm system continuously monitors all gas sources, displaying their status and offering visual cues for active sources.
Integrated Communication Protocols
Supports both MODBUS TCP/IP and RS485 RTU for easy integration with existing hospital systems and external monitoring devices.
Third Source Option
Includes an additional port for LOX, a compressor, or a third cylinder to provide flexibility for backup gas sources or specialised setups.
Leakage Monitoring for Safety
Monitors potential leakage on non-active sources, alerting users to any issues with the reserve side and enhancing overall system safety.
Maintenance Without Interruption
Perform service and maintenance operations while the manifold continues to function, ensuring no gas supply disruption during critical times.
Simple and Quick Installation
The manifold comes with a pre-installed back plate to simplify installation.
Optional Terminal Unit Test Point
Provides easy access for testing and servicing, ensuring the manifold operates efficiently and meets safety standards.
Gas type(s) | O2, Air, Air800, N2O, CO2, (all medical gases) |
---|---|
Nominal flow | 200 m3/h |
Cylinder inlet pressure | 300 bar (30 000 kPa) / 200 bar (20 000 kPa) |
LOX or Compressor inlet pressure | 8 - 14 bar (800 - 1 400 kPa) |
3rd source standby manifold pressure | 7 - 10 bar (700 - 1 000 kPa) |
Outlet nominal pressure | 4,5 bar ( 450 kPa) (8 bar Air800) |
Inlet connection | 2x W21,8×1/14“M, 1xM20x1F |
Outlet connection | G3/4“M |
Outlet pressure relieve valve | 6,8 bar (including manual activation) (12 bar Air800) |
Intermediate pressure relieve valve | 17 bar (including manual activation) |
Pressure relieve valve pipe dimension | ø 15 mm |
Testing point | NIST QC or QC in national standard |
Alarm | Integrated with touch screen |
Alarm power supply | 24VAC + added trafo 110V-240V |
Alarm languages | EN, FR, SE, IT, messages in any language in latin letters can be set |
Integrated communication protocols | MODBUS TCP/IP and RS485 RTU |
Output relay | 2x NO/NC, 1A max |
Regulatory status | MDD 93/42/EEC, EN ISO 7396-1, EN 60601-1-2, SIS HB 370 |
Loading... ... loading table ... |
Item No. | Code | Gas | Cylinder pressure | QC |
---|---|---|---|---|
073400045S | DUPLEX PNP200 O2 GCE T03 | O<sub>2</sub> | 300 | NIST |
073400046S | DUPLEX PNP200 O2 GCE T03 | O<sub>2</sub> | 200 | NIST |
073400047S | DUPLEX PNP200 AIR GCE T03 | Medical Air | 300 | NIST |
073400048S | DUPLEX PNP200 AIR GCE T03 | Medical Air | 200 | NIST |
073400049S | DUPLEX PNP200 AIR8 GCE T03 | Instrumental Air | 300 | NIST |
073400050S | DUPLEX PNP200 AIR8 GCE T03 | Instrumental Air | 200 | NIST |
073400051S | DUPLEX PNP200 O2 GCE T03 | O<sub>2</sub> | 300 | SS |
073400054S | DUPLEX PNP200 O2 GCE T03 | O<sub>2</sub> | 200 | SS |
073400055S | DUPLEX PNP200 AIR GCE T03 | Medical Air | 300 | SS |
073400056S | DUPLEX PNP200 AIR GCE T03 | Medical Air | 200 | SS |
073400057S | DUPLEX PNP200 AIR8 GCE T03 | Instrumental Air | 300 | SS |
073400058S | DUPLEX PNP200 AIR8 GCE T03 | Instrumental Air | 200 | SS |