The GCE Non-Return Valves prevent the backflow of medical gases, ensuring the safe flow of gases without contamination.
The GCE Non-Return Valves are designed for use in medical central gas systems to ensure that gas does not flow back from equipment and pipes through the central gas system. This feature is crucial, particularly when technical air is drawn from medical air pipes for use in laboratories. By preventing backflow, the GCE Non-Return Valves maintain the integrity and safety of the medical gas supply.
The GCE Non-Return Valves are designed for use in medical central gas systems to ensure that gas does not flow back from equipment and pipes through the central gas system. This feature is crucial, particularly when technical air is drawn from medical air pipes for use in laboratories. By preventing backflow, the GCE Non-Return Valves maintain the integrity and safety of the medical gas supply.
Complete Unit
The medical non-return valve unit includes a non-return valve (NRV) with a flow direction arrow, lockable medical shut-off valves, soldering pieces, nuts, and a gas-specific medical quick coupling (QC) for medical breathing air.
Ease of Testing
The non-return medical gas valve is easy to test.
Versatile Quick Coupling
The QC can be used for checking pressure, performing leak tests, and taking gas samples, enhancing its versatility.
Optional Instrumental Air QC
The non return valve unit can also be delivered with a QC for instrumental air, providing additional flexibility.
Complete Unit
The medical non-return valve unit includes a non-return valve (NRV) with a flow direction arrow, lockable medical shut-off valves, soldering pieces, nuts, and a gas-specific medical quick coupling (QC) for medical breathing air.
Ease of Testing
The non-return medical gas valve is easy to test.
Versatile Quick Coupling
The QC can be used for checking pressure, performing leak tests, and taking gas samples, enhancing its versatility.
Optional Instrumental Air QC
The non return valve unit can also be delivered with a QC for instrumental air, providing additional flexibility.
Gas type(s) | O2, Air, Air-800 |
---|---|
Opening pressure | 0.06 bar (6 kPa) |
Pressure class | PN16 |
Regulatory status | Degreasing for Oxygen use no CE–marking |
Loading... ... loading table ... |
Item No. | Description | Gas | Total Length |
---|---|---|---|
329000825 | Non return valve unit O2 DN15 | O2 | 415 mm |
325397676 | Non return valve unit AIR DN15 | AIR | 415 mm |
329000826 | Non return valve unit Air–800 DN15 | Air–800 | 415 mm |
325397873 | Non return valve unit O2 DN25 | O2 | 505 mm |
325397677 | Non return valve unit AIR DN25 | AIR | 505 mm |
325397777 | Non return valve unit AIR-800 DN25 | AIR-800 | 505 mm |
325397874 | Non return valve unit O2 DN40 | O2 | 932 mm |
325397678 | Non return valve unit AIR DN40 | AIR | 932 mm |
325397875 | Non return valve unit AIR-800 DN40 | AIR-800 | 932 mm |
You can have confidence in our global network
Copyright © 2024 GCE. All rights reserved.
GCE Group
Turmstrasse 30
6321 Steinhausen
Zug
Switzerland